Hello. I'm using a Shimadzu GC 14A with FID and an RTX 5 capillary column. I have optimized all my parameters and have checked with Shimadzu and they concur. They sent me very arcane instructions on cleaning the detector. I am planning to replace the nozzle, but would like to avoid cleaning the detector if possible: it seems very detailed and laborious. Has anyone cleaned an FID detector like this? If so would you mail or post about your experience? thanks! Adam -- _________________ Adam Finkelstein adamf@vtaix.cc.vt.edu http://sunsite.unc.edu/bees/adamf/home.htmlReturn to Top
I m an student in Spectrochemistry and my subject's trainee is the study of an Essential Oil of Patchouly by Mass Spectrometry coupled with gas chromatography. So, I search for mass spectra of the Patchouly oil like ... - Patchoulenone M=218 C15 H22 O - Isopatchoulenone M=218 C15 H22 O - Norpatchoulenol M=206 C14 H2 O - Pogostol M=222 C15 H26 O - 1 alpha - 5 alpha Epoxy - alpha Guaiene M=220 C15 H24 O - 1 beta - 5 beta Epoxy - alpha Guaiene M=220 C15 H24 O - 1,10 Epoxy alpha Bulnesene M=220 C15 H24 O - alpha Patchoulone M=220 C15 H24 O - beta Patchoulone M=220 C15 H24 O - 5 oxo Patchoulol M=236 C15 H24 O2 - alpha Guaienone M=218 C15 H22 O - alpha Cedrenal M=218 C15 H22 O - beta Patchoulenone M=218 C15 H22 O - gamma Selinene ? - Pogostone M=224 C12 H16 O4 - alpha Elemene M=204 C15 H24 - Beta Bulnesene M=204 C15 H24 Thank you for your help.Return to Top
On 20 Jan 1997 15:29:27 -0500, SCROODReturn to Topwrote: }has anyone had any luck with amine analysis }using mass spec? } }any advice would be appreciated. } } }pete Sure I have Pete, what kind of amines are you looking at? }
gbird@superlink.net wrote: } } On 20 Jan 1997 15:29:27 -0500, SCROODReturn to Top} wrote: } } }has anyone had any luck with amine analysis } }using mass spec? } } } }any advice would be appreciated. } } } } } }pete } } Sure I have Pete, what kind of amines are you looking at? } } } i don't know i need a little advice on sample prep. (pH...etc.) and the proper column and column temp. does this help? pete
The complete abstracts of issue 2/6 of European Mass Spectrometry are now available on our web site: http://www.impub.co.uk These abstracts and those of all previously published issues are searchable. If anyone cannot access the WWW and would like a text version e-mailed to them, please send a message to me. -- Ian Michael IM Publications Publishers of: 6 Charlton Mill European Mass Spectrometry Charlton Spectroscopy Europe Chichester Journal of Near Infrared Spectroscopy West Sussex PO18 0HY NIR news United Kingdom Tel: +44-1243-811334 Fax: +44-1243-811711 E-mail: ian.michael@impub.demon.co.uk Web site: http://www.impub.co.ukReturn to Top
Do there exist alternate suppliers of ball bearing grease for Alcatel turbomolecular pumps? We are finding out how costy the syringe refills are... Thank you, Daniel Michaud Departement de physique Universite LavalReturn to Top
Karl J. Treier of UniTech wrote: } } I was trying to reach the Teknivent website and it appears to have gone. } Has the company ? } } -- } UniTech } 680 Northland Boulevard } Suite 9 } Cincinnati } OH 45240, USA } } Phone: 1-800-989-0144 / (513) 825-0144 } Fax: (513) 825-0163 } E-Mail: info@uni-tech.com } Web site: http://www.uni-tech.com I found this company information, TEKNIVENT CORP., MARYLAND HEIGHTS, MO at SciQuest (http://sciquest.com). You can send them a email directly from the web site. Good Luck, ____________________________________________________________________ Joe Bumgarner, Jr. SciQuest - "Internet Solutions for Science" jbumgarner@sciquest.com "http://sciquest.com" Site Director Phone: 919-732-5813 FAX: 919-782-3123 ____________________________________________________________________Return to Top