You can now measure 8 independent thermocouples (C,E,J,K,T,R, & S types) simultaneously with your PC using either DOS or Windows at low cost. Temperature monitor plugs directly into serial port of PC for direct display of temperature vs. time in either tabular or graphic format with data storage to disk. The monitor comes complete with software program for PC. For further details contact Lazar Research Labs. Inc. at 1-800-824-2066 in the U.S. or email service@lazarlab.com or fax 1-213-931-1434.Return to Top
l major in catalysis. my catalyst is alumina supported molybdenum. And molybdenum is nitrided. so Mo is Mo2N not MoO3. l tried to meassur this sample by uv-vis DRS. But lencounterd some problem. Whenever l measure this sample, the peak shape is different with each other. The sample wasnot moved and measurmet was continuosly. How i greproducibel peak data?? Anybody help me.. Thank you for your kindness..Return to Top
Anyone know of online (www or ftp) sources for reference spectra (uv, vis, ir, etc.)?Return to Top
SLH wrote: > > Anyone know of online (www or ftp) sources for reference spectra (uv, > vis, ir, etc.)? Check out some of the following links. http://www.galactic.com/galactic/_gala/data.htm http://www.lut.fi/ltkk/tite/research/color/lutcs_database.html http://www.che.utexas.edu/~dls/ir/ir.html http://wwwchem.uwimona.edu.jm:1104/spectra/index.html http://wwwchem.uwimona.edu.jm:1104/spectra/UVIndex.html http://wwwchem.uwimona.edu.jm:1104/spectra/MSIndex.html http://info.arnold.af.mil/epa/entdat.htm -- --------------------------------------------------------------------------- Jim Holler Phone: 606-257-5884 Department of Chemistry FAX: 606-323-1069 University of Kentucky Email: holler@pop.uky.edu Lexington, KY 40506-0055 WWW: http://www.uky.edu/ArtsSciences/Chemistry/ http://www.uky.edu/~holler http://www.uky.edu/~holler/periodic/periodic.html ---------------------------------------------------------------------------Return to Top
Hi all who knowns the file format of spectra made with the clinical Magnetic Resonance with field of 1.5T of the Philips (NT15 acs) manufacturer. I must decode the signal FID and the spectra from this file. Thanks Giacomo Belli giac@dfc.unifi.itReturn to Top
On 1996-11-13 palmenj@gov.on.ca said: >Does anybody know the UV lamba max for Digitoxin (C41H64O13 >- CAS# 71-63-6?? >Thanks in advance! >J-P From Clarke's "Isolation and Identification of Drugs" 1st edition 1969 p303 Digitoxin in sulfuric acid, Maxima 235mu (E1%,1cm 270) 340mu (E1%,1cm 240) 420mu (E1%,1cm 240) 485mu (E1%,1cm 230) Minima 265,375,440 Interestingly, this data is not listed in the second edition (1986) Regards, Al Kind, Tech Lab Mgr: Microchem Lab U-193,Univ of CT Storrs CT 06269-4193, Phone / FAX (860)486-6126 Net-Tamer V 1.06H For HP100/200 & OG700 - RegisteredReturn to Top
Hello, Does anyone have reference to a PC card which will enable interfacing to an existing EDS system which is not windows based? I have an older EDS system which runs on a DEC. I would like to interface to Windows. Any clues?? Respectfully, JerryReturn to Top
On 11/13/96 8:18AM, in messageReturn to Top, Giampiero Amato wrote: > In article , Joseph Kurusingal > wrote: > > > I am interested in an holographic filter which can block 488 > > nm argon ion laser radiation and transmit radiation from 500 > > nm to 2000 nm. The transmission band need not be flat, but > > known. Oriel is apparently selling a holographic filter which > > can transmit upto 650 nm, but does not have any information on > > waht happens after 650 nm. I would appreciate information on > > a supplier for this device. > > > Did you try Kaiser Optical in Ann Arbor Michigan? They design and manufacture holographic optics and filters. They do have filters for the visible and near-IR regions. I know they have notch filters for the 488 nm and 785 nm laser lines. They use them in their Raman systems. Eric Johnson